I/O MODULE Power supply

61KZ010249 PSU

  • 5 V / 3 A 主模块供电输出
  • 高转换效率
  •  辅助的 24 V/ 2 A 电子保护输出
  •  过载电流和短路保护
  • 集成总线终端电阻 Integrated bus termination resistor
  • 状态和诊断 LED 显示

 Download datasheet
Datasheet download 资料下载

 

General Data
Housing dimensions  (Width x height x depth)22.5 mm x 99.0 mm x 114.5 mm
Weight95 g (without  connectors), 107 g (with connectors)
Permissible operating temperature+5° to +55°C
Permissible storage and transport temperature-25° to +85°C
Permissible humidity10% to 95%, not condensing
Permissible air pressure  (operation)80 to 106 kPa (up to  2000 m above sea level)
Permissible air pressure  (storage and transport)70 to 106 kPa (up to3000 m above sea level)
Degree of protectionIP20 according to IEC 60529
Connection method for connectorsSpring cage terminals
Conductor cross-section (power connector)0.2 to 2.5 mm2 (24 – 12 AWG)
Functional earth connectionTo the DIN rail with spring contact
Mode state visual indicatorsInput power (POWER), bus power 1 (BP1) and bus power 2 (BP2) LED lamps on front panel

 

Power supply
Main power supply VM24 V DC (-15% ÷ + 20% according to IEC 61131-2)
Maximum allowed ripple5% of supply voltage (according to IEC 61131-2)
Current consumption from main supply3 A max
Supply overvoltage protection on VMUnidirectional Zener clamp (Vz > 30 V)
Supply reverse polarity protectionInput shunt diode, reverse connected
Supply fuse5 A, not replaceable by the user
Input power visual indicatorsGreen LED lamp, lighted if supply is present (POWER)
Local bus power #15 V DC / 3 A, regulated
Local bus power #1 protectionsOvercurrent, catastrophic overvoltage
Local bus power #1 visual indicatorsLocal bus power #1 visual indicators
Local bus power #224 V DC / 2 A, unregulated
Local bus power #2 capacitive load120 μF max
Local bus power #2 protectionsOvercurrent
Local bus power #2 visual indicatorsGreen LED lamp, lighted if supply is present (24V)

 

Bus termination
Bus termination resistor120Ω

 